Copper Oxide as Mediator for the Amperometric Determination of Hydrogen Peroxide

 

 

Copper oxide (CuO) was investigated as a mediator for the amperometric determination of hydrogen peroxide. Screen-printed carbon electrodes (SPCEs) have been prepared with chemical modification by CuO. The basic electrochemical behaviour of these sensors was investigated and their ability for the detection of hydrogen peroxide was tested. The electrodes can be used as amperometric detectors in flow injection analysis (FIA) with working potentials of around –100 mV vs the reference electrode (Ag/AgCl/3M NaCl).

 

[DOWNLOAD FULL TEXT HERE]

 

REFERENCES

BOYER A, KALCHER K, PIETSCH R. 1990. Voltammetric behavior of perborate on prussian-bluemodified carbon paste electrodes. Electroanalysis 2: 155-161. 

CHI Q, DONG S. 1995. Amperometric biosensors based on the immobilization of oxidases in a Prussian blue film by electrochemical codeposition. Analytica Chimica Acta 310: 429-436.

COX JA, JAWORSKI RK. 1990. Mechanism of the mediated reduction of hydrogen peroxide at an electrode modified with a film containing a basic form of iridium oxide. Journal of Electroanalytical Chemistry and Interfacial Electrochemistry 281: 163-170.

FERNANDEZ-ROMERO JM, LUQUE DE CASTRO MD. 1993. Flow-through optical biosensor based on the permanent immobilization of an enzyme and transient retention of a reaction product. Analytical Chemistry 65: 3048-52.

GARGONYTE R, MALINAUSKAS A.1998. Amperometric sensor for hydrogen peroxide based on Cu2 O or CuO modified carbon paste electrode. Fresenius J Analytical Chemistry 360: 122-123.

HANAOKA S, LIN JM, YAMADA M. 2001. Chemiluminescent flow sensor for H2 O2 based on the decomposition of H2 O2 catalyzed by cobalt(II)– ethanolamine complex immobilized on resin. Analytica Chimica Acta 426: 57-64.

KARYAKIN AA, KARYAKINA EE, GORGON L. 1996. Prussian-Blue-based amperometric biosensors in flow-injection analysis. Talanta 43: 1597-1606.

LEI C-X. HU, S-Q, SHEN G-L, YU R-Q. 2003. Immobilization of horseradish peroxidase to a nano-Au monolayer modified chitosan-entrapped carbon paste electrode for the detection of hydrogen peroxide. Talanta 59: 981-988.

LI J, DASGUPTA PK. 2000. Measurement of atmospheric hydrogen peroxide and hydroxymethyl hydroperoxide with a diffusion scrubber and light emitting diode-liquid core waveguide-based fluorometry. Analytical Chemistry 72: 5338-47.

LUQUE G, RODRIGUEZ MC, RIVAS GA. 2005. Glucose biosensors based on the immobilization of copper oxide and glucose oxidase within a carbon paste matrix. Talanta 66: 467-471.

MATSUBURA C, KAWAMOTO N, TAKAMURA K. 1992. Oxo[5,10,15,20-tetra(4-pyridyl) porphyrinato]titanium(IV): an ultra-high sensitivity spectrophotometric reagent for hydrogen peroxide. Analyst 117: 1781-84.

OUNGPIPAT W, ALEXANDER PW, SOUTHWELLKEELY P. 1995. A reagentless amperometric biosensor for hydrogen peroxide determination based on asparagus tissue and ferrocene mediation. Analytica Chimica Acta 309: 35-45.

OYAMA N, ANSON FC. 1986. Catalysis of the electroreduction of hydrogen peroxide by montmorillonite clay coatings on graphite electrodes. J Electroanalytical Chemistry and Interfacial Electrochemistry 199: 467-470.

RAZOLA SS, RUIZ BL, DIEZ N, MARK HB, KAUFFMANN J-M. 2002. Hydrogen peroxide sensitive amperometric biosensor based on horseradish peroxidase entrapped in a polypyrrole electrode. Biosensors & Bioelectronics 17: 921-928.

RICE ME, GALUSZ, ADAMS RN. 1983. Graphite paste electrodes: Effects of paste composition and surface states on electron-transfer rates. J Electroanalytical Chemistry and Interfacial Electrochemistry 143: 89-102.

RUBIANES MD, RIVAS GA. 2007. Dispersion of multi-wall carbon nanotubes in polyethylenimine: A new alternative for preparing electrochemical sensors. Electrochemistry Communications 9: 480-484.

SCHACHL K, ALEMU H, KALCHER K, JEZKOVA J, SVANCARA I, VYTRAS K. 1997. Amperometric determination of hydrogen peroxide with a manganese dioxide-modified carbon paste electrode using flow injection analysis. Analyst 122: 985-990.

SCHACHL K, ALEMU H, KALCHER K, MODEREGGER H, SVANCARA I, VYTRAS K. 1998. Amperometric determination of hydrogen peroxide with a manganese dioxide film-modified screen printed carbon electrode. Fresenius J Analytical Chemistry 362: 194-200.

SLJUKIC B, BANKS CE, COMPTON RG. 2006. Iron oxide particles are the active sites for hydrogen peroxide sensing at multiwalled carbon nanotube modified electrodes. Nano Letters 6: 1556-58.

WANG CL, MULCHANDANI A. 1995. Ferroceneconjugated polyanilinemodified enzyme electrodes for determination of peroxides in organic media. Analytical Chemistry 67: 1109-14.

WANG J, MUSAMEH M. 2003. Carbon nanotube/ teflon composite electrochemical sensors and biosensors. Analytical Chemistry 75: 2075-79.

WANG J, MUSAMEH M, LIN Y. 2003. Solubilization of carbon nanotubes by Nafion toward the preparation of amperometric biosensors. J Am Chem Soci 125: 2408-09.

WENTZELL PD, VANSLYKE SJ, BATEMAN KP. 1991. Evaluation of acoustic emission as a means of quantitative chemical analysis. Analytica Chimica Acta 246: 43-53.